Hello, welcome to visit the official website of Shanghai Jifa Instrument Equipment Co., Ltd.!

Fiber Yarn Testing Equipment

JF-10 Fully Automatic Fiber Fineness Comprehensive Analyser

product manual

JF-10 automatic fiber fineness analyzer captures the longitudinal and cross-sectional micro-images of fibers by digital camera With the help of software intelligence, it can quickly test the longitudinal diameter, cross-sectional area and diameter of fib

  • description

  • compliant

  • Parameters

  • principle

  • Standard

It can be used to measure the diameter of animal fibers, chemical fibers, cotton and linen fibers. The number of fibers, average fineness, standard deviation, coefficient of variation and coarseness of fibers can be obtained. Through morphological analysis and diameter measurement of single fibers in blended products, the fiber content, yarn blending content and fabric of various blended products can be obtained. Blend content.

GB/T 10685-2007 "Wool Fiber Diameter Test Method Projection Microscope Method"

GB/T 20732-2006 Fiber Diameter Optical Analyser

GB/T 3364-2008 Test Method for Diameter and Root Number of Carbon Fibers

FZ/T 01057.3-2007 Textile Fiber Identification Experiment Method Part 3: Microscopic Method

AATCC 20-2013 Qualitative Analysis of Fibers

IWTO-47-2009 "Standard for Measuring Mean Diameter and Distribution of Wool Fiber by Optical Fiber Diameter Analyser"

"Ding"

IWTO-8-2004 Measurements of Wool Fiber Diameter Distribution and Wool and Other Animal Fiber Myelinization by Microscopic Projector

The Ratio Method

ISO 137:2015 Wool-Fiber Diameter Measurement-Projection Microscope Method

GB/T 12412-2007 Yak Down

GB/T 9998-2006 Xining Mao

GB/T 18267-2013 Cashmere

GB/T 16988-2013 "Determination of Mixture Content of Special Animal Fiber and Cotton and Wool"

GB/T 16254-2008 Mohair

GB/T 13835.6-2009 Test Method for Fineness of Rabbit Hair Fiber

GB/T 1977-2008 Camel Cashmere

FZ/T 30003-2009 Microprojection Method for Quantitative Analysis of Linen-Cotton Blended Products

FZ/T 32004-2009 Flax Cotton Blended Natural Yarn

SN/T 0756-1999 Microprojector Method for Quantitative Analysis of Import and Export Linen/Cotton Blended Products

ISO 17751-1:2016 (E). Quantitative Analysis of Cashmere, Wool and Other Animals by Animal Fiber Microscope

Fluff and its Mixture

FZ/T 01101-2008 Physical Method for the Determination of Textile Fiber Content

AATCC 20A-2014 Regulations on Quantitative Fiber Analysis

FZ/T 50002-1991 Testing of profile and hollowness of Profiled Fibers

AATCC 20-2017 Quantitative Fiber Analysis

CNS 2339-1 L3050-1


Functional characteristics

1. The measurement range of national standard is 2=200 micron, and that of instrument is 1-2000 micron.

2. Data correction function, full sample picture archiving function;

3. Data and reports are output by EXCEL. Format and statistics of reports can be changed according to user's requirements.

For Standards,

4. New development of personalized interface, custom observation multiple;

5. Automatically calibrate the scale to minimize operating errors.

6. By adding dynamic measurement to diameter and content experiments, the current field of view measurement marks can be retained and the measurement can be greatly improved.

Speed and accuracy;

7. It is used to observe the cross-sectional morphology of various chemical fibers, profiled fibers and hollow fibers and to measure the cross-sectional area.

8. Testing the profile and hollowness of profiled fibers meets the textile industry standards.

9. Fibers of various blended products can be obtained by analyzing the transverse morphology and measuring the area of single fibers in blended products.

Dimension content;

10. Using DMMAIT dynamic measurement marker automatic induction technology;

11. User-defined technology of new FTUD fiber types can be used to customize fiber types.

12. Provide a library of fibre samples with more than 50 kinds of fibers.

UV-M3 three-axis automatic control system:

1. Fast moving speed: up to 1500 pieces per minute, test the conventional carrier for 3 minutes.

2. Three-axis automatic step-by-step, easy to test and operate. After setting the initial parameters, the measurement can be completed automatically without human being.

Industrial intervention.

3. When the automatic step module is not used, it does not hinder the use of other manual functions.

Microscopic parameters:

1. Brand Specification: Olympus BX43 (Imported) Research-grade Positive Microscope for open field observation;

2. Optical system: UIS2 infinite distance correction optical system, lens using environmentally friendly lead-free glass material.

3. Focusing: The vertical motion distance of the carrier platform is not less than 25 mm, the stop position with the upper limit of coarse focusing is fixed, the torque of the coarse tuning knob is adjustable, and the minimum fine-tuning scale unit is less than 1 micron.

4. Observing lens barrel: wide field trinocular lens barrel with an inclination of 30 degrees

5. Illumination device: built-in transmission light Kohler illuminator, 6V30W halogen lamp, light quantity pre-adjusting switch, light intensity light emitting diode indicator lamp, fluorescent balance filter

6. OBJECTIVE: Flat-field achromatic OBJECTIVE

4X (N.A. 0.1, W.D. 18.5mm)

10X (N.A. 0.25, W.D. 10.5mm)

20X (N.A. 0.4, W.D. 12mm)

40X (N.A. 0.65, W.D. 0.6mm spring)

7. Carrier platform: high wear-resistant ceramic overlay carrier platform for right-hand low-position coaxial drive buttons.

8. Eyepiece: 10X wide field eyepiece with 22 field of vision;

9. OBJECTIVE CONVERTER: FIVE-HOLE OBJECTIVE CONVERTER

10. Concentrator: Abbe Concentrator, N.A. > 1.1

Camera parameters:

1. Brand Specification: Panasonic CP750

2. High definition: 700 lines

2. High-sensitivity day-to-night conversion function: 0.08Lux (color mode); 0.008Lux (black-and-white mode).

4. Electronic Sensitivity Improvement: Automatic (up to 32 times); Manual (up to 512 times)

5. Electronic shutter speed is 1/50 to 1/120000 seconds

6. Fog penetration compensation: Clear images can be obtained in fog and haze weather.

7. Chinese Menu


Equipment name and model

Usage/Remarks

Number

Fiber Fineness Analysis Software

Data measurement and calculation

1

Microscope

OLYMPUS(4X、10 X、20 X、40 X)

1

Automatic stepping module

UV-M3

1

Color/Black-and-White Camera

Panasonic CP750

1

Computer

Lenovo raises the sky 4900

1

Printing

HP M203d

1

Fibre seeder

UV-SBQ2

1

Fixed-length sampler

UV-DL

1

Software accessories

Acquisition Card, Instructions, CD-ROM, Encryption Fussy

1

Kazakhstan slicer

Sample preparation

1

Length flannel

Length sample preparation

1

Density clamp

Density sampling equipment

1

Micrometer

Metrological transmission

1

Certificate of Metrology of the Chinese Academy of Metrology

Micrometer

1


Shanghai Jifa Instrument Equipment Co., Ltd. Official WeChat
Add:

2/F, Building 3, No. 3599, Yuanjiang Road, Minhang District, Shanghai

Factory address:

No. 1, Lane 19, Zhongyi East Road, Yucheng Town, Jinshan District

Fax:

021-33321965

E-mail:

jifayiqi@163.com

Copyright © 2019 Shanghai Jifa Instrument Equipment Co., Ltd. Technical support: Jiedian Technology